Product Description
Product Overview |
We offer the wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non-contact type sensors (Black Bodies), available in the temperature range -80°C to 1700°C. Our calibration equipment products include Liquid bath, Dry Block Furnaces, Black Bodies, Reference Junction Units, and Master Sensors. These calibrators are available in both Portable and Laboratory models. These highly accurate & reliable units are offered at very competitive prices. |
|
Features |
Provide a superior thermal environment calibration equipment for probe immersion as no air gap exists between the probe and the medium Thermal coupling is therefore much better than the alternatives described, and the stirring results in very even heat distribution throughout the medium. Methanol is used for temperature below 0°C, water from 0 to80°C and silicon oil for up to 250°C.
Devices |
Temperature Range (°C) |
Stability (°C) |
Calibration Volume (mm) |
Medium |
Calsys -80/50 |
-80 to 50 |
0.05 |
100*130*200 |
Methanol |
Calsys -40/50 |
-40 to 50 |
0.05 |
90*90*150 |
Methanol |
Calsys -35/50 |
-35 to 50 |
0.05 |
220*180*250 |
Methanol |
Calsys -35/200 |
-35 to 200 |
0.01 |
157*142*127 |
Silicon oil |
Calsys 120SP |
0 to 120 |
0.1 |
Dia 24 * 100(L),
3*6 hole |
Silicon oil |
Calsys 250 |
50 to 250 |
0.1 |
Dia 90*140(D) |
Silicon oil |
Calsys 300SP |
50 to 250 |
0.1 |
100*150*200 |
Silicon oil |
|
Provides the most convenient, portable facilities for checking & calibrating industrial probes and they are usually reasonable rapid heating and cooling device. The unit consists of a specially designed heating block which has located internal holes for the probes. Although the block temperature is accurately controlled, any indication provided should be used for guidance only. As with any comparison technique, a certified sensor and indicator should be used to measure the block temperature and used as a reference for the test probe. Two types of unit are available; portable units which can be taken on to plant for the on-site calibration and laboratory units to which industrial sensors are brought as required.
Devices |
Temperature Range (°C) |
Stability (°C) |
Calibration Volume (mm) |
Calsys -15/110 |
-15 to 110 |
0,1 |
Dia 24 * 300(L) (2 holes of 6.5, 2 holes of 8.5) |
Calsys 650 |
50 to 650 |
0.1 |
Dia 32 * 150(L), 4 holes of 6.5 * 120(D) |
Calsys FB |
50 to 650 |
0.1 |
Dia 150 * 385(D) |
Calsys 1200 |
250 to 1200 |
1 |
Dia 37 * 215(L), (2*6&2*8 holes) * 160(D) |
Calsys 1200L |
300 to 1200 |
0.5 |
Dia 37 * 240(L), (2*6&2*8 holes) * 160(D) |
Calsys 1200 3Z |
300 to 1200 |
0.4 |
Dia 37 * 240(L), (2*6&2*8 holes) * 160(D) |
Calsys 1500L |
500 to 1500 |
1 |
Dia 37 * 245(L), (2*6&2*8 holes) * 140(D) |
|
Black bodies are reference sources calibration equipment used for testing infrared systems. They are required in the industry for calibration of pyrometers, infrared line scanners or cameras. In a laboratory, they are part of benches for characterization of complex optronic systems. Tempsens offers a wide range of black bodies to cover all Customers needs.
Devices |
Temperature Range (°C) |
Stability (°C) |
Emissivity |
Calibration Volume (mm) |
Calsys 500BB |
50 to 500 |
1.0 |
0.95 |
Dia 100 |
Calsys 1200BB |
300 to 1200 |
1.0 |
0.99 |
37±1 mm dia& 140mm depth |
Calsys 1500BB |
500 to 1500 |
1.0 |
0.99 |
37±1 mm dia& 140mm depth |
Calsys 1700BB |
500 to 1700 |
2.0 |
0.97 |
dia 29 mm, 235 mm depth |
|
|
|